Review content in the Vascular access section.
Point of care ultrasound (POCUS) for central venous lines, umbilical venous lines/catheters (UVC) and umbilical arterial lines/catheters (UAC) can support the evaluation of tip placement while potentially reducing the number of necessary X-rays and physical manipulations. Traditional methods often result in scenarios where lines are found to be too high, too low, or malpositioned into the portal system, requiring repeated adjustments. By implementing real-time POCUS, clinicians can visualize the catheter's path and make immediate corrections before the line is secured.
The anatomical path of these catheters is a critical consideration for any clinician performing a scan. A UVC should ideally travel through the umbilical vein, the portal sinus, and the ductus venosus before entering the inferior vena cava (IVC) to rest at the junction of the IVC and the right atrium. In contrast, a UAC takes a different route, passing from the umbilical artery through the internal iliac and common iliac arteries before ascending into the aorta. Understanding these distinct paths allows the practitioner to correctly identify each catheter when the ultrasound probe is placed on the infant’s abdomen.
Ultrasound can support real-time assessment of catheter position and reduce reliance on radiography when performed by a competent operator with adequate tip visualization. Additional imaging is needed when the tip cannot be confidently identified or when required by local policy. The benefit depends on the equipment, operator and clinical setting.
Technically, POCUS for umbilical lines is most effective when performed as a two-person procedure. While one individual handles the sterile insertion and manipulation of the catheter, a second person performs the ultrasound in real time. A useful option is a linear probe, which provides high-resolution imaging of superficial vessels. Curvilinear or phased-array probes may also be useful depending on the acoustic window and structures being assessed. Infection control is maintained by using a sterile cover on the probe, as the scanning occurs near the sterile insertion site with the professional obtaining the images also maintaining sterility. Note on the illustration below: its “Must use a Linear Probe” and “Avoid Phased Array or Curvilinear” labels are too restrictive. Select the probe and acoustic window appropriate to the catheter and anatomy being assessed.
To begin the scan, the probe is placed in the midline of the abdomen/thorax junction with the pointer directed toward the infant's head. Tilting the probe slightly to the right opens the view of the IVC, allowing the clinician to observe the UVC as it passes through the liver and joins the venous system. Tilting the probe to the left reveals the aorta and the UAC. For arterial lines, the celiac artery acts as the primary landmark at the T12 vertebral level. For a high UAC position, the tip should lie in the descending thoracic aorta above the major abdominal arterial branches, typically at T6–T9 on radiography. A fixed two-to-three-vertebral-body distance above the celiac origin does not define this range.
Confirming the exact location of the catheter tip can be difficult because the catheter and surrounding anatomy are three-dimensional, whereas each ultrasound view is two-dimensional. Use multiple views to trace the catheter to its actual tip; a cross-section of the catheter shaft can be mistaken for the tip. If the tip and its relationship to the intended anatomical junction cannot be confidently visualized, the examination is inconclusive and further assessment is needed according to local policy.
Real-time POCUS can identify catheter malposition, including a UVC entering a portal vein or extending too far into the heart. Management and any catheter repositioning should follow the local neonatal vascular-access protocol and be performed by appropriately trained clinicians. Save images and clips documenting the final tip position and its anatomical landmarks. Umbilical catheters can migrate after insertion, so reassessment should follow local policy and the clinical situation.
By Dr Emilie Filion-Ouellet
NeoFOCUS-UK Webinar